Upgrade Failed
If the Upgrade Succeeded screen does not appear, it means that the upgrade failed to complete
successfully, in which case you should do the following:
1. Power off the GCS1204 and remove its housing.
2. Using a jumper cap, short the jumper on the mainboard labeled J17. The diagram below indicates the
jumper location on the GCS1204 board:
3. Power on the GCS1204. It will now work with the factory default rmware.
4. Repeat the rmware upgrade procedure.
5. After the upgrade procedure completes, power off the switch, remove the jumper cap from J17, close
the housing, and power the GCS1204 on again.